8. INSTALLATION
WARNING!
Refer to the Safety chapters.
Before the installation
Before the installation of the appliance, re-
cord the information below from the rating
plate. The rating plate is on the bottom of
the appliance casing.
• Model ...........................
• PNC .............................
• Serial number ....................
8.1 Built-in appliances
• Only use the built-in appliances after
you assemble the appliance into correct
built-in units and work surfaces that
align to the standards.
8.2 Connection cable
• The appliance is supplied with the con-
nection cable.
• Replace the damaged mains cable only
with the spare parts cable. Speak to
your local Service Centre.
Two phase connection
1.
Remove the cable sheath from black
and brown wires.
2.
Apply a new cable sheath.
N
L1
N
L
230V~ 400V 2~N
L2
One phase connection — 230 V~
Two phase connection — 400 V 2 ~
N
Green — yellow Green — yellow
N Blue and gray Blue and gray N
L Black and brown Black L1
Brown L2
8.3 Assembly
min.
50mm
min.
500mm
min.
2mm