ELECTROLUX-REX PX780UOV Manual de usuario Pagina 12

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 11
5.
Replace the rating label (it is near the
gas supply pipe) with the one for the
new type of gas supply. You can find
this label in the package of the injec-
tors supplied with the appliance.
If the supply gas pressure is changeable
or different from the necessary pressure,
you must fit an applicable pressure ad-
juster on the gas supply pipe.
8.3 Adjustment of minimum level
To adjust the minimum level of the burner:
1.
Light the burner.
2.
Turn the knob on the minimum posi-
tion.
3.
Remove the control knob.
4.
With a thin screwdriver, adjust the by-
pass screw position. If you change
from natural gas 20 mbar to liquid
gas, fully tighten the adjustment
screw in. If you change from liquid
gas to natural gas 20 mbar, undo the
by-pass screw approximately 1/4 of a
turn for screw B, 1/3 of a turn for
screw A.
A
B
A)
Minimum adjustment screw for
dual burner both crowns
B)
Minimum adjustment screw for
dual burner internal crown
5.
Make sure the flame does not go out
when you quickly turn the knob from
the maximum position to the mini-
mum position.
8.4 Electrical connection
Make sure that the rated voltage and
type of power on the rating plate agree
with the voltage and the power of the
local power supply.
This appliance is supplied with a mains
cable. It has to be supplied with a cor-
rect plug which can hold the load that
the rating plate rates. Make sure that
you install the plug in a correct socket.
Always use a correctly installed shock-
proof socket.
Make sure that there is an access to
the mains plug after the installation.
Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
There is a risk of fire when the appli-
ance is in connection with an extension
cable, an adapter or a multiple connec-
tion. Make sure that the ground con-
nection agrees with the standards and
regulations.
Do not let the power cable to heat up
to a temperature higher than 90° C.
To prevent contact between the cable
and the appliance below the hob use the
clamps which are on the side of the cabi-
net.
A
A)
Rigid copper pipe or flexible pipe of
stainless steel
8.5 Replacement of the
connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown
(or black) phase wire.
12
www.electrolux.com
Vista de pagina 11