4. Assemble the parts, follow the same
procedure backwards.
5. Replace the rating plate (it is near the
gas supply pipe) with the one for the
new type of gas supply. You can find
this plate in the package supplied with
the appliance.
If the supply gas pressure is changeable
or different from the necessary pressure,
you must fit an applicable pressure
adjuster on the gas supply pipe.
8.4 Adjustment of minimum level
To adjust the minimum level of the
burners:
1. Light the burner.
2. Turn the knob on the minimum
position.
3. Remove the knob.
4. With a thin screwdriver, adjust the
bypass screw position (A for external
crown and B for internal crown).
5. If you change:
• from natural gas G20 20 mbar to
liquid gas, fully tighten the bypass
screw in.
• from liquid gas to natural gas G20
20 mbar, undo the bypass screw
approximately 1/4 of a turn.
WARNING!
Make sure the flame does not
go out when you quickly turn
the knob from the maximum
position to the minimum
position.
8.5 Electrical connection
• Make sure that the rated voltage and
type of power on the rating plate agree
with the voltage and the power of the
local power supply.
• This appliance is supplied with a mains
cable. It has to be supplied with a
correct plug which can hold the load
that the rating plate rates. Make sure
that you install the plug in a correct
socket.
• Always use a correctly installed
shockproof socket.
• Make sure that there is an access to
the mains plug after the installation.
• Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug.
• There is a risk of fire when the
appliance is in connection with an
extension cable, an adapter or a
multiple connection. Make sure that the
ground connection agrees with the
standards and regulations.
• Do not let the power cable to heat up
to a temperature higher than 90° C.
To prevent contact between the cable and
the appliance below the hob use the
clamps which are on the side of the
cabinet.
ENGLISH