A) Rigid copper pipe or flexible pipe of
stainless steel
8.6 Connection cable
To replace the connection cable use only
the special cable or its equivalent. The
cable type is: H05V2V2-F T90.
Make sure that the cable section is
applicable to the voltage and the working
temperature. The yellow / green earth wire
must be approximately 2 cm longer than
the brown (or black) phase wire.
8.7 Building In
min. 55 mm
min. 650 mm
830 mm
min. 450 mm
30 mm
480 mm
A) supplied seal
B) supplied brackets
CAUTION!
Install the appliance only on a
worktop with flat surface.
8.8 Installing hob under the
hood
If you install the hob under a
hood, please see the
installation instructions of the
hood for the minimum
distance between the
appliances.
8.9 Possibilities for insertion
The panel installed below the hob must be
easy to remove and let an easy access in
case a technical assistance intervention is
necessary.
Kitchen unit with door
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
A) Removable panel
B) Space for connections
Kitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
www.electrolux.com14