Electrical connection
The appliance is set up for a single-phase 230V feeling
voltage. The connection has to be carried out in
compliance with the current directives and law
dispositions.
Before connecting the hob make sure that:
The shaping valve and the electrical system can stand
the appliance load (see the serial number indicated on
the rating plate):
The feed system of the appliance has a proper earth
connection, according the laws in force;
The tap or the single-pole circuit breaker are easy to be
reached from the installed appliance.
Mount on the cable a suitable tap for the load and
connect it to a proper safety tap.
If a straight connection to the electricity is desired, it is
necessary to put a single-pole, with a minimum opening
of 3mm dimensioned to the load and in compliance with
the current directives, between the appliance and the
network.
The brown phase wire (coming out from the L terminal
on the terminal board) must be always connected to the
phase of the feeding network.
In any case the feeding wire has to be positioned so that
it cannot reach, anywhere in its length, a temperature
higher than 90°C.
An example of optimal current path is indicated on
picture 10. The wire is guided by the employment of
clamps fixed on the side of the furniture, in order to
avoid any contact with the appliance under the hob
8
Picture 10
Comentarios a estos manuales